Description
SPECIFICATIONS:
- Permeate Flow: 2,000 gpd (7.6 m3/d)
- CaCl2 Rejection: 86%
- CaCl2 Rejection (minimum/maximum): 83%/94%
*Expected calcium rejection for a typical 500 ppm well water is 96% at 13 gfd operating flux and 25°C.
- Configuration: Low Fouling Spiral Wound
- Membrane Polymer: Composite Polyamide
- Membrane Active Area: 80ft2 (7.43m2)
- Feed Spacer: 34 mil (0.864 mm) with biostatic agent
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
- 500 ppm CaCl2
- 75psi (0.52 MPa) Applied Pressure
- 77°F (25°C) Operating Temperature
- 15% Permeate Recovery
- 6.5 – 7.0 Feed pH
STANDARD OPERATING LIMITS:
- Maximum Applied Pressure: 600 psig (4.16 MPa)
- Maximum Chlorine Concentration: < 0.1 PPM
- Maximum Operating Temperature: 113°F (45°C)
- pH Range, Continuous (Cleaning): 2-10 (1-12)
- Maximum Feedwater Turbidity: 1.0 NTU
- Maximum Feedwater SDI (15 mins): 5.0
- Maximum Feed Flow: 16 GPM (3.6 m3/h)
- Minimum Ratio of Concentrate to Permeate Flow for any Element: 5:1
- Maximum Pressure Drop for Each Element: 10 psi
The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.
Weight | 4.5 kg |
Be the first who will post an article to this item!
Solutions You Need, Technologies You Trust!
Hydranautics is one of the global leaders in membrane technology. We apply state-of-the-art technology to manufacture industry’s most advanced, high-performance membrane products.