Description
PRODUCT SPECIFICATIONS | ||||||||
Product name | Item no. | Element type | Active membrane area | Permeate flow rate | Typical rejection | Minimum rejection | Feed water | Pressure |
Aquaporin Inside® CLEAR Plus 4040 | 40104 | Fiberglass, wet | 85 ft² 7.9 m² | 2,100 GPD | 99.0% | 98.5% | 2,000 ppm NaCl | 125 psi (8.6 bar) |
Aquaporin Inside® CLEAR Plus 4040XL | 40105 | Tape wrap, wet | 97 ft² 9.0 m² | 2,500 GPD | 99.0% | 98.5% | 2,000 ppm NaCl | 125 psi (8.6 bar) |
The stated product performances are tested at 25°C (77°F), 15% recovery, pH 7-8. Permeate flow rate and rejections are stated after a minimum of 60 min operation. | ||||||||
Individual element permeate flow rate may vary ± 15%. |
ELEMENT DIMENSIONS | |||||
Product name | A | B | C | D | |
Aquaporin Inside® CLEAR Plus 4040 series | 40.0 / 1016.0 | 1.05 / 26.7 | 0.75 / 19.1 | 3.95 / 100.3 | |
Dimensions (inches / millimeters) |
OPERATING SPECIFICATIONS | |||
Maximum operating pressure |
41.4 bar (600 psi) for fiberglass 20.7 bar (300 psi) for tape wrap |
Maximum feed water turbidity | 1 NTU |
Maximum feed flow rate | 3.6 m3/h (16 gpm) | pH range (operation) | 3–10 |
Maximum operating temperature | 45°C (113°F) | pH range (short-term cleaning, 25°C / 77°F) | 1–12 |
Maximum pressure drop | 0.7 bar (10 psi) | Free chlorine tolerance | < 0.1 ppm |
Maximum feed water SDI | 5 (15 min) |
ADDITIONAL INFORMATION |
Permeate from the first hour of operation should be discarded. Do not use this initial permeate for consumption. |
To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution. Rinse out the preservative solution before use. |
Elements contained in the boxes must be kept dry at room temperature (5–35°C / 41–95°F) and should not be stored in direct sunlight. |
Keep elements moist at all times after initial wetting. |
The presence of free chlorine and other oxidizing agents can cause premature membrane failure. Since oxidation damage is not covered under warranty, Aquaporin A/S recommends removing residual free chlorine by pretreatment prior to membrane exposure. |
Weight | 4.5 kg |
Be the first who will post an article to this item!
Add a comment
Aquaporin is a water technology pioneer, headquartered in Denmark with operations in Singapore, Turkey, the United States, and China. We are committed to rethinking water filtration with biotechnology to solve global water challenges. Our groundbreaking Aquaporin Inside® technology, inspired by nature and rooted in Nobel Prize-awarded research, is integrated into all our solutions and used to clean water in industries, in our homes, and by NASA in space.